Laser Plastic Welding
LQ-Power
LQ-Integration
LQ-Hybrid
Learn About Laser Welding
Process Monitoring
Transmission Measurement
Articles
LQ-Integration    
The LQ-Integration series features advanced plastics welding technology for seamless integration with production lines.

 
Specifications
       
Technical specifications for LQ-Integration
Laser beam source Water-cooled fiber-coupled diode laser
Wavelength: 980 mm (also available as 808 nm, 915 nm, or 940 nm)
Laser power: 30-210 W (high power option up to 400 W)
Fiber optic: 0.3 mm diameter (other diameters optional)
Fiber optic: with integrated connection, breakage, and temperature monitoring
Working field 1.8” x 1.8” (45 x 45 mm), 4.3” x 4.3” (110 x 110 mm), 6.1” x 6.1” (154 x 154 mm)
Clamping technology Pneumatic top-down clamping
Electronic supervision of end positions
Inductive measurement system to record the welding process
Adapter plates for a variety of clamping tools
System control Siemens 315 F failsafe CPU
Siemens TP 1708 touch panel controls
Parameter management
Industrial PC for process data archiving (optional)
Software LPKF ProSeT software for programming the welding path
Online process monitoring Process monitoring with: time control, process control, speed control
Interfaces 24 V control I/O lines, Ethernet, RD-232, PROFIBUS, Anybus
Power requirements Voltage 115V/20A (Universal Power Supply)
Current: max. 3 kW
Air supply: 6 bar dry air
Environmental conditions Maximum operating temperature: 104º F (40º C)
Maximum humidity: 80% at 77º F (25º C)
Cooling system Integrated water/air cooling unit
Integrated water heat exchanger (optional)
Options Clamping tool encoding
Air-cooled clamping tools (patent pending)
Advanced burn detection (patent pending)
Remote maintenance option
Dimensions (W/H/D) Control cabinet: 31.5” x 31.5” x 78.7” (800 x 800 x 2,000 mm)
Welding unit: 15.7” x 27.6” x 25.6” (400 x 700 x 650 mm)
*This machine is designed as a Class 1 Laser Product